|
|
基本情報 |
|
氏名 |
佐伯 香織 |
氏名(カナ) |
サエキ カオリ |
氏名(英語) |
Saeki Kaori |
所属 |
獣医学部 獣医保健看護学科 |
職名 |
准教授 |
researchmap研究者コード |
R000000677 |
researchmap機関 |
岡山理科大学 |
Comparison of Glucose Fluctuations between Day- and Night-Time Measured Using a Continuous Glucose Monitoring System in Diabetic Dogs
Akihiro MORI, Miyuki KURISHIMA, Hitomi ODA, Kaori SAEKI, Toshiro ARAI, Toshinori SAKO
|
|
Monitoring of blood glucose concentration is important to evaluate the diabetic status of dogs. Continuous glucose monitoring systems (CGMS) have been applied in veterinary medicine for glucose monitoring in diabetic dogs. The purpose of the study was to evaluate the daily glycemic profiles obtained with CGMS and compare glucose fluctuations between day- and night-time in diabetic dogs. Five diabetic dogs were used in this study and were treated with either NPH insulin or insulin detemir. For data analyses, day-time was defined as 9:00 am–9:00 pm and night-time as 9:00 pm–9:00 am. Using glucose profiles, we determined the mean glucose concentrations (1- and 12-hr intervals), and times spent in hyperglycemia >200 mg/dl or hypoglycemia <60 mg/dl. None of the parameters differed significantly between day-time and night-time in dogs treated with NPH insulin or insulin detemir. In conclusion, this study confirmed, using CGMS, that there are no differences in glucose fluctuations between day- and night-time, in diabetic dogs on a similar feeding regimen and insulin administration.
Journal of Veterinary Medical Science
https://doi.org/10.1292/jvms.12-0123
|